www.geolabs.co.uk |
GEOLABS Limited . . . Tel: +44 (0)1923
892 190 . . Fax: +44 (0)1923
892 191
UKAS Accreditation |
|
| Click here for the www.ukas.org website page specific to Geolabs Limited | ||
| Schedule Details - TESTING LABORATORY No. 1982 | ||
| Category 0 - Permanent Laboratory
Materials/Products Tested - Laboratory Contact - John Masters Issue No: 010 Date: 25 January 2011 |
Address:
Geolabs Ltd. Telephone: 09123 892 190 |
|
| Types of Test | Standard Specifications | |
| Moisture content - oven drying method |
BS1377:Part 2:1990 | |
| Liquid limit - cone penetrometer |
BS1377:Part 2:1990 | |
| Plastic limit | BS1377:Part 2:1990 | |
| Plasticity index and liquidity index | BS1377:Part 2:1990 | |
| Particle size distribution - wet sieving |
BS1377:Part 2:1990 | |
| Particle size distribution - dry sieving |
BS1377:Part 2:1990 | |
| Particle size distribution - sedimentation pipette method |
BS1377:Part 2:1990 | |
| Particle density - small pyknometer |
BS1377:Part 2:1990 | |
| Dry density/moisture content relationship (2.5 kg rammer) |
BS1377:Part 4:1990 | |
| Dry density/moisture content relationship (4.5 kg rammer) |
BS1377:Part 4:1990 | |
| California Bearing Ratio (CBR) | BS1377:Part 4:1990 | |
| One dimensional consolidation properties | BS1377:Part 5:1990 | |
| Permeability in a triaxial cell | BS1377:Part 6:1990 | |
| Unconfined compressive strength - load frame method (loads from 0.12 to 24 kN) |
BS1377:Part 7:1990 | |
|
Undrained shear strength |
BS1377:Part 7:1990 | |
|
Undrained shear strength |
BS1377:Part 7:1990 | |
| Shear strength - small shearbox |
BS1377:Part 7:1990 | |
| Residual strength - small ring shear apparatus |
BS1377:Part 7:1990 | |
| Shear strength - large shearbox |
BS1377:Part 7:1990 | |
|
Effective shear strength |
BS1377:Part 8:1990 | |
|
Effective shear strength |
BS1377:Part 8:1990 | |
| Accelerated permeability test | Evironment Ageny R & D Technical Report P1-39B/TR/2:2003 |
|
|
Effective shear strength |
Documented In-House Method Test Procedure 38 | |
|
Effective shear strength |
Documented In-House Method Test Procedure 38 | |